Explosion-proof Zirconia Oxygen Analyzer

Click on the image to check the artwork
unit price: negotiable
min amount:
amount:
period for delivery: Consignment Deadline Days
area: Beijing
Expiry date : Long Effective
last update: 2022-05-16 22:20
view count: 117
enquiry
Company Profile
 
 
Product details

Description

The explosion-proof zirconia oxygen analyzer not only is a practical and reliable automatic analytical instrument and also the explosion-proof zirconia oxygen analyzer has the characteristics of high sensitivity, good reproducibility and stability, wide range, automatic switching, fast response and continuous online measurement. Therefore, the Explosion-proof Zirconia Oxygen Analyzer can quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces that to achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.


Application
The explosion-proof zirconia oxygen analyzer is mainly used in: 

★ Coal-fired power plants

★ Waste incineration power plants

★ Biomass power plants

★ Sulfuric acid plants

★ Chemical plant boilers

★ Hazardous waste treatment boilers

★ Heating station boilers

★ Steel plants, steel mills

★ Petroleum Pipeline pressure station boilers and other fields


Main Features
★ No special ground wire required.

★ High accuracy and wide range ratio.
★ Zirconia probe wear resistance and corrosion resistance.
★ Strong resistance to field interference.
★ Easy to install, the response is fast and widely used.

★ Convenient replacement of components, easy maintenance, and reduced use cost.


Specification

Items

Specifications

Oxygen concentration:

0.001~100 vol%

Output signal:

4~20mA DC (maximum load resistance 750Ω)

Setting range:

0~20.6 vol% (0~30% can be set)

Digital communications:

Support Modbus 232/485 and Ethernet (selectable)

Heating time:

Approx. 20 min.

Repeatability:

±0.5vol% maximum value of set range.

Zero drift:

1.5 vol% maximum value of set range (60 days)

Response time:

Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing).

Power supply:

220±10%VAC

Installation:

Flange mounting

Limit output:

Provide settable upper and lower limit outputs (optional)

Temperature control accuracy:

0~700℃ (Floating temperature calculation)


Equipment system accuracy:

±1%F.S.

Digit display mode:

4 bit LED nixie tube display

Operation:

Menu button operation

Calibration operation:

Three parameters on-line calibration

Equipment power:

Approx. 10W (Excluding heating power)

Heating power:

50W (average), able to supply maximum 150W power output

Environmental conditions:

Ambient temperature 0~70℃, relative humidity ≤ 90%

Protection level:

IP65

Electrical interface:

M20

Explosion-proof level:

EXdII ct6 GB (only for explosion-proof type product)


Detector length:

180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)

(Note: Detector length is from the detector tip to flange)